Product Features
High transparent materials providing easy monitoring of the puncture site.
Variety band length for broad selection.
Good flexibility making patient comfortable.
Availability: | |
---|---|
Quantity: | |
KRAT
Selestem
High transparent and soft material, Easy monitoring of the puncture site and comfortable to wear
Air injection syringe, Easy to adjust the pressure
Flexible belt, Convenient to fix
Marker point design, Make accurate hemostasis
Small and large airbag design, Make compression concentration
What is the function of radial artery tourniquet?
The radial artery tourniquet is mainly used by medical personnel to assist compression hemostasis after removing the puncture needle or indwelling needle in arterial puncture surgery. The pressure in air balloons is easily adjusted by specially designed syringe.
What is the function of radial artery tourniquet?
The radial artery tourniquet is mainly composed of compression hemostatic pad, blood reflux support frame, compression bridge, adjustable fixed bandage and fixed bandage perforation.
The radial artery tourniquet is used for direct measurement of arterial blood pressure and blood gas measurement for hemostasis and coverage protection after puncture of radial artery and dorsalis pedis artery, as well as hemostasis and coverage protection after pulling out of various puncture and indwelling needles.
The radial artery tourniquet is used for compression hemostasis after radial artery catheter intubation.
Size Matrix of Radial Artery Tourniquet
No. | Cat.No. | Description | |||||||
1 | KRAT-S1 | Band Length 230mm with safety airbag | |||||||
2 | KRAT-M1 | Band Length 270mm with safety airbag | |||||||
3 | KRAT-L1 | Band Length 290mm with safety airbag | |||||||
4 | KRAT-S0 | Band Length 230mm without safety airbag | |||||||
5 | KRAT-M0 | Band Length 270mm without safety airbag | |||||||
6 | KRAT-L0 | Band Length 290mm without safety airbag |
High transparent and soft material, Easy monitoring of the puncture site and comfortable to wear
Air injection syringe, Easy to adjust the pressure
Flexible belt, Convenient to fix
Marker point design, Make accurate hemostasis
Small and large airbag design, Make compression concentration
What is the function of radial artery tourniquet?
The radial artery tourniquet is mainly used by medical personnel to assist compression hemostasis after removing the puncture needle or indwelling needle in arterial puncture surgery. The pressure in air balloons is easily adjusted by specially designed syringe.
What is the function of radial artery tourniquet?
The radial artery tourniquet is mainly composed of compression hemostatic pad, blood reflux support frame, compression bridge, adjustable fixed bandage and fixed bandage perforation.
The radial artery tourniquet is used for direct measurement of arterial blood pressure and blood gas measurement for hemostasis and coverage protection after puncture of radial artery and dorsalis pedis artery, as well as hemostasis and coverage protection after pulling out of various puncture and indwelling needles.
The radial artery tourniquet is used for compression hemostasis after radial artery catheter intubation.
Size Matrix of Radial Artery Tourniquet
No. | Cat.No. | Description | |||||||
1 | KRAT-S1 | Band Length 230mm with safety airbag | |||||||
2 | KRAT-M1 | Band Length 270mm with safety airbag | |||||||
3 | KRAT-L1 | Band Length 290mm with safety airbag | |||||||
4 | KRAT-S0 | Band Length 230mm without safety airbag | |||||||
5 | KRAT-M0 | Band Length 270mm without safety airbag | |||||||
6 | KRAT-L0 | Band Length 290mm without safety airbag |
content is empty!