Availability: | |
---|---|
Quantity: | |
KPTCA
1. Conical core wire has excellent conveying performance.
2. Super lubrication hydrophilic coating can provide very good transport performance.
3.3 Wing balloon grooves ensure that the balloon has a minimal profile, making it easier to pass through narrowing.
4. Advanced laser bonding technology makes the transition between balloon and catheter easier, and also provides good crossoverability.
5. The soft tapered tip provides a smooth transition from the guide wire port to the balloon catheter, making a great cross through the blood vessel or even a curved one.
6. Cutting edge laser forming technology is needed to make the balloon's entrance much smaller. This allows the balloon to pass through the lesion more easily.
7. To improve stability and torque transfer, we choose UV curing adhesive.
8. Positive and negative pressure test can maintain the air tightness of the whole balloon catheter. Different technical specifications can meet different requirements.
9. Perfect high pressure resistance, NP-12ATM, RBP-22ATM.
10. Provide accurate expansion pressure concentration, extremely low compliance, low expansion rate from NP to RBP.
11. The short shoulder design can minimize the excessive expansion of both sides of the balloon, mainly focusing on the expansion of the lesion area and reducing the injury to normal blood vessels during the operation.
12. Clear repackaging image, the balloon is still easy to remove after expansion.
P/atm D/mm | Tolerance of Compliance:±5% | ||||||
6 (NP) | 8 | 10 | 12 | 14 | 16 (RBP) | 18 | |
1.5 | 1.50 | 1.53 | 1.56 | 1.59 | 1.62 | 1.65 | 1.68 |
2.0 | 2.00 | 2.03 | 2.06 | 2.09 | 2.12 | 2.15 | 2.18 |
2.5 | 2.50 | 2.54 | 2.58 | 2.61 | 2.64 | 2.67 | 2.70 |
2.75 | 2.75 | 2.79 | 2.83 | 2.86 | 2.89 | 2.92 | 2.95 |
3.0 | 3.00 | 3.04 | 3.08 | 3.11 | 3.14 | 3.17 | 3.21 |
3.5 | 3.50 | 3.55 | 3.60 | 3.64 | 3.69 | 3.73 | 3.77 |
4.0 | 4.00 | 4.05 | 4.10 | 4.15 | 4.20 | 4.25 | 4.30 |
Size Matrix of PTCA Balloon Catheter:
L/mm D/mm | 10 | 15 | 20 | 25 | 30 | 35 | 40 |
1.5 | √ | √ | √ | √ | - | - | - |
2.0 | √ | √ | √ | √ | √ | - | - |
2.5 | √ | √ | √ | √ | √ | √ | √ |
2.75 | √ | √ | √ | √ | √ | √ | √ |
3.0 | √ | √ | √ | √ | √ | √ | √ |
3.5 | √ | √ | √ | √ | √ | √ | √ |
4.0 | √ | √ | √ | √ | √ | √ | √ |
1. Conical core wire has excellent conveying performance.
2. Super lubrication hydrophilic coating can provide very good transport performance.
3.3 Wing balloon grooves ensure that the balloon has a minimal profile, making it easier to pass through narrowing.
4. Advanced laser bonding technology makes the transition between balloon and catheter easier, and also provides good crossoverability.
5. The soft tapered tip provides a smooth transition from the guide wire port to the balloon catheter, making a great cross through the blood vessel or even a curved one.
6. Cutting edge laser forming technology is needed to make the balloon's entrance much smaller. This allows the balloon to pass through the lesion more easily.
7. To improve stability and torque transfer, we choose UV curing adhesive.
8. Positive and negative pressure test can maintain the air tightness of the whole balloon catheter. Different technical specifications can meet different requirements.
9. Perfect high pressure resistance, NP-12ATM, RBP-22ATM.
10. Provide accurate expansion pressure concentration, extremely low compliance, low expansion rate from NP to RBP.
11. The short shoulder design can minimize the excessive expansion of both sides of the balloon, mainly focusing on the expansion of the lesion area and reducing the injury to normal blood vessels during the operation.
12. Clear repackaging image, the balloon is still easy to remove after expansion.
P/atm D/mm | Tolerance of Compliance:±5% | ||||||
6 (NP) | 8 | 10 | 12 | 14 | 16 (RBP) | 18 | |
1.5 | 1.50 | 1.53 | 1.56 | 1.59 | 1.62 | 1.65 | 1.68 |
2.0 | 2.00 | 2.03 | 2.06 | 2.09 | 2.12 | 2.15 | 2.18 |
2.5 | 2.50 | 2.54 | 2.58 | 2.61 | 2.64 | 2.67 | 2.70 |
2.75 | 2.75 | 2.79 | 2.83 | 2.86 | 2.89 | 2.92 | 2.95 |
3.0 | 3.00 | 3.04 | 3.08 | 3.11 | 3.14 | 3.17 | 3.21 |
3.5 | 3.50 | 3.55 | 3.60 | 3.64 | 3.69 | 3.73 | 3.77 |
4.0 | 4.00 | 4.05 | 4.10 | 4.15 | 4.20 | 4.25 | 4.30 |
Size Matrix of PTCA Balloon Catheter:
L/mm D/mm | 10 | 15 | 20 | 25 | 30 | 35 | 40 |
1.5 | √ | √ | √ | √ | - | - | - |
2.0 | √ | √ | √ | √ | √ | - | - |
2.5 | √ | √ | √ | √ | √ | √ | √ |
2.75 | √ | √ | √ | √ | √ | √ | √ |
3.0 | √ | √ | √ | √ | √ | √ | √ |
3.5 | √ | √ | √ | √ | √ | √ | √ |
4.0 | √ | √ | √ | √ | √ | √ | √ |